Abstract:
On the basis of the service environment, the reasons of 20
# elbow 3 times failure in a short period were investigated by means of physical and chemical property testing, microstructure analysis, corrosion scale analysis, flow rate and erosion corrosion simulated results. The results indicated that CO
2 corrosion occurred at the elbow during the process of CO
2 huffing and puffing, and the loose and porous FeCO
3 corrosion scale formed. Meanwhile, the solid particles in the medium caused erosion corrosion on the outer arc side of the elbow. Under the synergistic effect of CO
2 corrosion and erosion corrosion, the FeCO
3 scale was destroyed, and metal was exposed on the outer arc side of the elbow, resulting in a rapid thinning of the outer arc sidewall and finally perforation. Finally, suggestions were given to avoid or slow down the rapid failure of such elbows.