高级检索

    某油田站场区域阴极保护现场试验与方案

    Design of Regional Cathodic Protection Scheme for an Oilfield Station

    • 摘要: 以某油田站场的埋地管道与储罐底板为研究对象,开展了详细的现场馈电试验与三维数值模拟计算,基于现场试验与模拟结果,确定所需保护电流及阳极地床分布方案,并进行了示范应用。结果表明:利用现场馈电试验及数模计算确定的方案能够获得预期的保护效果,在存在7个储罐的罐区,要使单个储罐电位达到-850 mV,需要设置两口深井阳极,总电流输出需达到80 A。

       

      Abstract: Detailed on-site feeding tests and 3D simulation were conducted on the buried pipelines and tank bottom plates of an oilfield station. Based on the on-site feeding test results and numerical simulation results, the needed protection current and anode ground bed distribution scheme were determined, and the demonstration application was carried out. The results show that the scheme determined by on-site feeding tests and numerical simulations could achieve the expected protection effect. In a tank farm with 7 tanks, two deep-well anodes with a total current output of 80 A were required to achieve a potential of -850 mV for a single tank.

       

    /

    返回文章