Advanced Search
    ZHAO Xiaoyan, CHEN Chonggang, YU Fengchang, CUI Xinan, LI Chaofa. Corrosion Evaluation and Material Selection of the Overhead System of H2S Stripping Tower in Hydrogenation Unit[J]. Corrosion & Protection, 2018, 39(1): 63-67. DOI: 10.11973/fsyfh-201801014
    Citation: ZHAO Xiaoyan, CHEN Chonggang, YU Fengchang, CUI Xinan, LI Chaofa. Corrosion Evaluation and Material Selection of the Overhead System of H2S Stripping Tower in Hydrogenation Unit[J]. Corrosion & Protection, 2018, 39(1): 63-67. DOI: 10.11973/fsyfh-201801014

    Corrosion Evaluation and Material Selection of the Overhead System of H2S Stripping Tower in Hydrogenation Unit

    • The operating condition of H2S stripping tower was simulation, the general corrosion, pitting corrosion and stress corrosion cracking sensitivity of 20#, 304L, 321 and 316L in wet H2S environment were evaluated by immersion corrosion test, potentiostatic anodic polarization method and U-bent specimen test. The results showed that the corrosion resistance of 20# steel was poor, and hydrogen blistering was easy to occure at low temperature. 304L, 321, 316L austenitic stainless steels and 2205 duplex steel had a low corrosion rate and much better corrosion resistance. The pitting resistance of 304L and 321 stainless steels was a bit poor compared with 316L and 2205 steels, and honeycomb localized corrosion caused by slight pitting appeared. The existence of H2S observably enhanced the pitting sensitivity of austenitic stainless steels in the environment containing Cl-. The welding samples of 304L, 321 and 316L stainless steels had a good resistance to stress corrosion cracking.