Calculation Method of Radioactivity of Activated Corrosion Products in Primary Circuit Pipeline
-
-
Abstract
Different theoretical models, model equations, advantages and their disadvantages are reviewed. Combined with the migration characteristics of activated corrosion products in the primary circuit, a calculation method is derived to evaluate the radioactivity of activated corrosion products 60Co and 58Co in the primary circuit of a pressurized water reactor. The reliability of the method is demonstrated by comparing the Pactole calculation results.
-
-