ZHANG Rui-xiang, DUN Xiao-bao, WANG Ze-tian, HAO Hui-yu, ZHANG Yu. EDTA High-temperature Method Chemical Cleaning for Three-pressure Heat Recovery Steam Generator in a New Power Plant[J]. Corrosion & Protection, 2015, 36(4): 389-392.
Citation:
ZHANG Rui-xiang, DUN Xiao-bao, WANG Ze-tian, HAO Hui-yu, ZHANG Yu. EDTA High-temperature Method Chemical Cleaning for Three-pressure Heat Recovery Steam Generator in a New Power Plant[J]. Corrosion & Protection, 2015, 36(4): 389-392.
ZHANG Rui-xiang, DUN Xiao-bao, WANG Ze-tian, HAO Hui-yu, ZHANG Yu. EDTA High-temperature Method Chemical Cleaning for Three-pressure Heat Recovery Steam Generator in a New Power Plant[J]. Corrosion & Protection, 2015, 36(4): 389-392.
Citation:
ZHANG Rui-xiang, DUN Xiao-bao, WANG Ze-tian, HAO Hui-yu, ZHANG Yu. EDTA High-temperature Method Chemical Cleaning for Three-pressure Heat Recovery Steam Generator in a New Power Plant[J]. Corrosion & Protection, 2015, 36(4): 389-392.
EDTA High-temperature Method Chemical Cleaning for Three-pressure Heat Recovery Steam Generator in a New Power Plant
Due to the complex system, the three-pressure heat recovery steam generator (HRSG) had a long cleaning period and the difficulty for controlling its temperature. A high-temperature chemical cleaning method with EDTA was suggested. The results showed that this method had a perfect cleaning effect, a simple cleaning process and a short cleaning period.