TESTING OF CORROSION BEHAVIORS OF STEEL BAR IN DEICING SALT BY USING ALTERNATE IMMERSION
-
-
Abstract
Corrosion velocity of steel bar in deicing salt of different concentrations was mensurated by weight-loss method in alternate immersion test which simulated the natural corrosion environment.The corrosion surface was observed with scanning electron microscopy.The corrotion rate was minimum at the concentration of deicing salt from 15% to 20% and maximum at the concentration of 3.5%.
-
-