Advanced Search
    YANG GANG, LIANG Gen-sheng, CAI HONG. Yakela-Dalaoba Gas Well Downhole Tubing Corrosion and Protection Measures[J]. Corrosion & Protection, 2011, 32(12): 1001-1004.
    Citation: YANG GANG, LIANG Gen-sheng, CAI HONG. Yakela-Dalaoba Gas Well Downhole Tubing Corrosion and Protection Measures[J]. Corrosion & Protection, 2011, 32(12): 1001-1004.

    Yakela-Dalaoba Gas Well Downhole Tubing Corrosion and Protection Measures

    • Yakela-Dalaoba gas condensate field locates in Xinjiang Tarim Basin. The reservoir property belongs to high depth (5000-6000 m), high pressure (56-58 MPa), high temperature (146-150 ℃) and complex corrosion environment (high CO2, high Cl-, low pH , low H2S ). After the field was put into operation for 5 years, due to the occurrence of corrosion of underground pipes 15, 500 meters tubing were scrapped. After analyzing the Yakela-Dalaoba corrosive environment and the failure in hole tubing, the gas well downhole tubing corrosion protection measures and recommendations are proposed.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return