Advanced Search
    QIAO Pei-peng, LIU Fei-hua, ZHAO Wan-xiang. Corrosion Failure Analysis of Ductile Iron Potable Water Pipeline[J]. Corrosion & Protection, 2011, 32(8): 669-672.
    Citation: QIAO Pei-peng, LIU Fei-hua, ZHAO Wan-xiang. Corrosion Failure Analysis of Ductile Iron Potable Water Pipeline[J]. Corrosion & Protection, 2011, 32(8): 669-672.

    Corrosion Failure Analysis of Ductile Iron Potable Water Pipeline

    • The corrosion failure behavior of ductile iron potable water pipeline in a nuclear power plant was investigated by surface analysis method, X-ray diffraction and microbial technology. The results showed that tubercles caused by microbiologically influenced corrosion led to the pipeline failure directly. The local oxygen-concentration corrosion was another cause for accelerating the corrosion rate.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return