XING Shao-hua, LI Xiang-bo, YAO Ping, YAN Yong-gui, XU Li-kun, WU Jian-hua. Numerical Simulation Calculation of the Walls Potential of Copper Pipes Protected by Iron Sacrificial Anode[J]. Corrosion & Protection, 2008, 29(10): 622-624.
Citation:
XING Shao-hua, LI Xiang-bo, YAO Ping, YAN Yong-gui, XU Li-kun, WU Jian-hua. Numerical Simulation Calculation of the Walls Potential of Copper Pipes Protected by Iron Sacrificial Anode[J]. Corrosion & Protection, 2008, 29(10): 622-624.
XING Shao-hua, LI Xiang-bo, YAO Ping, YAN Yong-gui, XU Li-kun, WU Jian-hua. Numerical Simulation Calculation of the Walls Potential of Copper Pipes Protected by Iron Sacrificial Anode[J]. Corrosion & Protection, 2008, 29(10): 622-624.
Citation:
XING Shao-hua, LI Xiang-bo, YAO Ping, YAN Yong-gui, XU Li-kun, WU Jian-hua. Numerical Simulation Calculation of the Walls Potential of Copper Pipes Protected by Iron Sacrificial Anode[J]. Corrosion & Protection, 2008, 29(10): 622-624.
Numerical Simulation Calculation of the Walls Potential of Copper Pipes Protected by Iron Sacrificial Anode
The potential distribution on walls of different types of copper pipes protected by iron anode was calculated by BEASY software based on BEM method.The results showed that they had good agreement with the practically measured results,suggesting that in the distance of less than 350 mm,iron anode would provide well sacrificial protection to the copper pipes.