    APPLICATION OF SACRIFICIAL ANODE CATHODIC PROTECTION OF LATENT-OIL ELECTRIC PUMP IN NORTH OIL FIELD OF INDONESIA

    • The latent-oil eletric pump was corroded severely in the north oil field of Indonesia.The corrosion mechanism was analyzed based on the well liquid data.Mg alloy sacrificial anode cathodic protection has been adopted to protect the latent-oil eletric pump group effectively.