Advanced Search
    MA Xiao-ming, ZHANG Zhen. Corrosion Failure Analysis of Heating Furnace Tubes[J]. Corrosion & Protection, 2008, 29(4): 229-231.
    Citation: MA Xiao-ming, ZHANG Zhen. Corrosion Failure Analysis of Heating Furnace Tubes[J]. Corrosion & Protection, 2008, 29(4): 229-231.

    Corrosion Failure Analysis of Heating Furnace Tubes

    • The corrosion failure reasons of furnace tubes in a refinery were analyzed,based on test results of macrographic observation,mechanical test,metallography,SEM and X-ray Spectrum.Improvement measures of material selection,structure design and manufacturing process are also recommended.