CORROSION ANALYSES OF DILUTED STEAM GENERATING SYSTEM OF EA1123 ETHYLENE PLANT
-
-
Abstract
The leakage due to corrosion of the dilution steam generator of ethylene plant EA1123 occurred 13 times in recent 17 months.According to a detailed analysis of the corrosion reasons in the equipment and technology,main reason was regarded as that there was a mass of sulfide and alkali in water and subseguently NaOH-H2S-H2O corrosion system was formed.The localized corrosion perforation of the outer heat-exchange tube was caused by the strong acid and alkaline corrosion system produced by evaporating concentration of the corrosive medium in the dilution steam generator.Some protection measures are proposed.
-
-